The Normally Closed Switch Probe F88306B230G230LM (item number 1006968) combines spring-loaded contacting with a defined switching or sensing function. F88306B230G230LM combines electrical contacting with a switching signal so that DUT presence or position can be evaluated directly in the test sequence. In F88306B230G230LM, the normally closed function opens an initially closed contact at the defined actuation travel, allowing the test system to detect a mechanical state electrically. For F88306B230G230LM, spring force is 230 cN at a nominal travel of 4 mm. F88306B230G230LM is rated for 10 A continuous current with a typical contact resistance of 50 mΩ. F88306B230G230LM combines a pitch of 3.5 mm / 138 mil with tip style 06 (Serrated stepped) and a tip diameter of 2.3 mm.